Protection that keeps you inspection-ready.
We help commercial and residential customers stay protected, documented, and compliant across West Tennessee, East Arkansas, and North Mississippi.
We keep your property protected, your documentation current, and your inspections on track — across fire sprinklers, suppression systems, and backflow prevention.

Keep your property protected and your records ready for the next inspection. We handle design, installation, testing, and repair of wet, dry, pre-action, and deluge systems to NFPA 13 standards.
Schedule an Inspection →
When a kitchen or critical room goes down, every hour matters. We service kitchen hood systems, clean agent systems, and special hazard suppression to keep your operations running.
Schedule Hood Service →
We make annual backflow testing easier to understand, easier to schedule, and easier to close out correctly. Certified testing, paperwork submission, and fire-line coordination handled from start to finish.
Schedule Backflow Testing →Testing a fire-line backflow device is not the same as testing a lawn irrigation assembly. We understand both fire protection systems and backflow compliance — especially where they overlap.
Fire-line testing can require shutting down sprinkler water supply. We coordinate the shutdown, testing, and restoration so your building stays protected.
Disabling a fire line triggers alarms. We handle monitoring company notifications and fire department coordination so there are no false dispatches.
We process compliance paperwork, submit to water authorities, archive records, and track testing due dates so you never miss a deadline.
Most backflow testers don't understand sprinkler systems. Most sprinkler companies don't do backflow. We do both, which means cleaner accountability and fewer vendors to manage.

Each building has unique fire protection needs. We design and install the right system based on your occupancy, climate, and risk profile.
The most common system — pipes filled with pressurized water for immediate discharge. Cost-effective at $1–$3/sq ft. NFPA 13 compliant. Ideal for climate-controlled buildings.
Compressed air holds back water until a head activates. Designed for unheated warehouses, parking garages, loading docks, and cold storage where pipes could freeze.
Dual-trigger design requires fire detection AND head activation before water flows — virtually eliminating accidental discharge. Perfect for data centers, museums, and archives.
All open heads discharge simultaneously for total-flood response. Used in chemical plants, aircraft hangars, and high-hazard environments where fire spreads rapidly.
High-output heads suppress fires at the source. Reduces costs 30–50% versus in-rack sprinklers in warehouses while providing superior high-piled storage protection.
Aesthetically designed concealed heads, PEX/CPVC piping. $1–$2/sq ft new construction. 5–15% insurance discount. NFPA 13D/13R standards.
NFPA 25 sets the minimum inspection, testing, and maintenance schedule for water-based fire protection. We track every deadline so you stay ahead of the fire marshal, the water authority, and your insurer.
| Frequency | What's Inspected |
|---|---|
| Weekly | Control valve positions, gauges on dry/pre-action/deluge systems |
| Monthly | Wet pipe system gauges, control valve visual inspection |
| Quarterly | Water flow alarm testing, tamper switch testing, main drain test, FDC inspection |
| Annually | Full system inspection — all heads, hangers, pipes, fittings; dry/deluge valve trip test; spare head inventory; backflow testing |
| 5-Year | Internal pipe inspection for corrosion/obstruction; gauge replacement/calibration |
| 10-Year | Fire pump flow testing; hydrostatic testing |
| 20/50-Year | Sprinkler head sample testing/replacement (fast-response at 20 years; standard at 50 years) |
Keep your portfolio inspection-ready with recurring compliance support. We track testing schedules, provide documentation, and give you fewer surprises after every inspection.
Keep your kitchen open and compliant. We handle semi-annual hood service per NFPA 96, rapid response after discharge or system failure, and help you avoid unnecessary downtime.
Dependable coordination from design through closeout. We provide permit and inspection support, AHJ process familiarity, and closeout-ready documentation on your timeline.
Clear answers, simple scheduling, and no jargon. If you received a backflow notice or need sprinkler work at home, we explain the process plainly and handle the paperwork for you.
901-555-FIRE
dispatch@3alarmprotection.com
West Tennessee, East Arkansas, and North Mississippi
Clear communication, recurring service support, and paperwork handled with care. We understand both fire protection systems and backflow compliance — one team, one point of contact.